Loadcalc 2002 Trial VersioService and feeder sizing calculations for single family dwellings. It also prints panelboard directories in two sizes (4x6 inch and 6x8 inch) for inside the panelboard doors or covers. | |
Download |
Loadcalc 2002 Trial Versio Ranking & Summary
Advertisement
- License:
- Demo
- Publisher Name:
- Robert LaCapra
- Publisher web site:
- http://www.electrc.net
- Operating Systems:
- Win95,Win98,WinME,WinNT 3.x,WinNT 4.x,Windows2000,WinXP,Windows2003,Windows Vista Starter,Windows Vi
- File Size:
- 0.62 MB
Loadcalc 2002 Trial Versio Tags
- feeder News Feeder Automatic Document Feeder kadoatie feeder Cubic Inch Converter adf feeder inch sizing reduce inch fraction inch fraction denominator feeder load inch monitors 22 inch monitor 19 inch monitor 24 inch monitor 17 inch monitor 19 inch lcd monitor 20 inch monitor 23 inch monitor 24 inch lcd monitor sizing calculations feeder schedule
Loadcalc 2002 Trial Versio Description
Loadcalc 2002 performs service and feeder sizing calculations for single family dwellings. It also prints panelboard directories in two sizes (4x6 inch and 6x8 inch) for inside the panelboard doors or covers. The 2002 National Electrical Code is fully supported. Service/feeder load calculations for single dwelling units Standard Calculation Method (NEC Article 220), Optional Calculation Method (NEC Article 220-30), and Additional Loads in Existing Dwelling Units Calculation Method (NEC Article 220-31). Calculates net computed load in VA and amperes, and calculates the total service entrance load. Panelboard Directories: Prints directories for the inside of panelboard doors. Standard Calculation Method Demand Factoring: General Lighting, Small Appliance and Laundry Loads. Cooktop, Range, Wall Oven. Fixed Appliances. Largest Motor Load. Optional Calculation Method Demand factoring of 'other loads' as per NEC 220-30. Allows input of heating system type as per NEC Table 220-30, automatically determines the larger of heating or cooling load. Additional Loads In Existing Dwelling Units Load calculations for existing dwelling units presently served by a 120/240 volt or 120/208Y service. Quick Reference Tables From The '99 NEC Can be viewed on screen or printed. Grounding Electrode Conductor Sizes (NEC Table 250-94). Service/Feeder Conductor Sizes (NEC 310, Note 3). Cooking unit demand factors (NEC 220-19). File Save/Load Save individual data files for later recall. Specify default data directory Input up to four lines of data which will print at the top of your report. Print Preview & Printed Reports Print preview screens show reports as they will print. Professional, detailed printed reports. This release adds support for Windows Vista.
Loadcalc 2002 Trial Versio Related Software